Abstract

A few-mode microfiber knot resonator (FM-MKR) incorporating a polyvinyl alcohol (PVA) is investigated for measurement of relative humidity (RH). Two modes, such as HE 11 and HE 12 , are excited and interfered in a nonadiabatically tapered structure of the single-mode fiber (SMF). After making a tie with the few-mode microfiber, the FM-MKR is fabricated. In the FM-MKR, two modes, such as HE 11 and HE 12 , must be circulated within the optical knot and cross-coupled independently with a phase delay. By optimizing the diameter of the microfiber, the difference of group effective refractive indices between two modes is dramatically suppressed resulting in the improvement of RH sensitivity of the proposed FM-MKR.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call