Abstract

A method to attribute the short-term variability of blood pressure and heart rate of resting subjects to their various causes, using spectral techniques, is presented. Power spectra and cross-spectra are calculated for beat-to-beat values of R-R interval and blood pressure from subjects who were seated in a comfortable chair. Interval values as well as systolic, mean and pulse pressures show variations linked to respiration and to the so-called 10 s rhythm. The diastolic pressure values are scarcely influenced by respiration in the normal respiratory range (0·20–0·35 Hz), but do show 10 s variability. Relationships between pressure and interval variability which indicate that the 10 s variability in systolic pressure leads the interval variation by two to three beats become manifest in cross-spectra; however, no such lag is found between the respiration-linked variations in systolic pressure and intervals. It is argued that the technique presented provides a critical test for models of the fast regulation of the cardiovascular system.