Abstract

To determine the relationships between intraoperative hemodynamic parameters and delayed hemodynamic recovery after valve deployment and identify the predictive factors of delayed hemodynamic recovery by focusing on intraoperative hemodynamics in patients with transcatheter aortic valve replacement (TAVR). A retrospective study. A single university hospital. Sixty-four patients who underwent elective TAVR between 2015 and 2017. No intervention. The 64 patients were divided into the following 2 groups according to the time for recovery: systolic arterial pressure exceeded 90 mmHg and central venous oxygen saturation (ScvO2) exceeded 65%-delayed recovery (DR) (n = 36) group, and early recovery (ER) (n = 28) group. ScvO2 in the DR group was not lower than that in the ER group after induction of anesthesia. However, ScvO2 in the DR group gradually decreased and was lower than that in the ER group before valve deployment, despite improvement in blood pressure through the administration of vasopressor agents. ScvO2 monitoring during TAVR is useful to predict delayed recovery greater than 60 seconds after valve deployment in TAVR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.