For the purpose of this study, acoustic signals were generated by an Amplaid MK VI. An Amplaid 702 impedence meter was connected to its averaging section and to its computer. The stimuli were bursts of unfiltered white noise (UWN) and of narrow band white noise (NBWN; 30 db./oct/slope; central frequencies 1,000, 2,000, 4,000 Hz.) lasting 3-1,000 msec., at intensity of 105 db. SPL p.e. The following parameters were evaluated: stapedius contraction latency, amplitude, duration and recruitment time. It was found that latency was independent of the spectrum of the stimulus and its duration. Amplitude and recruitment time, on the other hand, were related to spectrum and duration, while duration of contraction was directly related to the duration of the stimulus only.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.