Abstract

This study was conducted to investigate the importance of the depth of chest compression in producing effective cardiopulmonary resuscitation (CPR) in animals, as indicated by cardiac output and mean arterial blood pressure. Cardiac output was measured by a modified indicator dilution technique in 8 anesthetized dogs, 6 to 12 kg body weight, during repeated 2-minute episodes of electrically induced ventricular fibrillation and CPR provided by a mechanical chest compressor and ventilator (Thumper). Chest compression exceeding a threshold value (xo) between 1.5 and 3.0 cm was required in each animal to produce measurable cardiac output. In particular, cardiac output (CO) was linearly related to chest compression depth (x) by an expression of the form CO = a(x-xo) for x greater than xo. The mean value of xo was 2.3 cm. A similar threshold for measurable blood pressure was observed in 7 of the 8 dogs, with a mean value of 1.8 cm. For chest compression of 2.5 cm or greater, relatively modest increases in chest compression depth caused relatively large changes in cardiac output.