Abstract

In this work, the pressure fluctuation pattern in the volute of a squirrel-cage fan is analyzed. Also studied is how this pattern is modified when a slight geometry change is introduced in the volute tongue. The study has been carried out on a commercial machine, used in automotive air conditioning units. A three-dimensional and unsteady numerical simulation of the flow in the complete machine has been carried out using the commercial code FLUENT. In this way, the pressure fluctuations in some locations near the volute wall have been obtained. The results of this numerical simulation have been compared to the sound pressure level spectra radiated by the fan, measured in a ducted test installation at the laboratory. The tendencies of the sound pressure levels measured at the blade passing frequency show a good correlation with the amplitudes of pressure fluctuations obtained numerically near the volute wall.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.