Abstract

Systolic time intervals (STI) are regarded as good indices of cardiac performance in many heart diseases. It must be considered, however, that they are temporally related to the cardiac contraction cycle and, therefore, may be modified by heart rate changes. Thus, it is necessary to define the possible relationship between STI and heart rate changes. In this study, changes in heart rate were induced by atrial and ventricular pacing. Tachycardia caused a proportional decrease of left ventricular ejection time (LVET) (y=275.142-1.0025 x, r=0.76, p less than 0.001 for atrial pacing and y=298.28-0.691 x, r=-0.75, p less than 0.001 for ventricular pacing, respectively), but did not modify the pre-ejection period (PEP) and the isometric contraction time (ICT) and the electromechanical interval (QS1). These results demonstrate that while LVET must be corrected for the changes in heart rate, no correction of PEP and ICT is necessary.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.