Abstract

To investigate the enhancement in ultrasound signal (US) in heart, for diagnostic purposes, as a function of size and number of injected air-filled microspheres by multivariate statistical methods. The US enhancement in left ventricle was measured after injection of 31 suspensions of air-filled albumin microspheres divided on and injected in six dogs. The relationship between the size of microspheres between 1-38 microns and the US enhancement was explored by Pearson's product moment correlation analysis, ordinary least-squares regression, principal component regression (PCR) and partial least-squares regression (PLS). Relative advanced algorithms such as PCR and PLS were required to achieve accurate in vivo/in vitro correlation. The most effective microsphere sizes contributing to US enhancement in left ventricle in dogs were estimated to be in the 7-15 microns range. In general, the effective in vivo sizes are dependent on the type of formulation due to the surprisingly large active in vivo sizes found for the tested concept. PCR and PLS are suitable methods for in vivo/in vitro correlation, especially for covariated and noisy data.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.