Abstract

Data examining the effect of operator years in practice and volume on adverse events (AE) after cardiac catheterization in patients with congenital heart disease is limited. Data were prospectively collected using a multi-center registry (C3PO). 10,885 catheterizations performed between 02/07 and 06/10 at eight institutions were included. AE rates were risk-adjusted for hemodynamic vulnerability, procedure type risk group, and age and compared between operators with different years in practice (YIP) and volume. AE occurred in 13% of procedures. Operators with less than five YIP had higher adjusted odds of any AE (OR 1.42, 95% CI 1.14-1.77) or a high severity AE (OR 1.35, 95% CI 1.04-1.75), when compared with operators with 5 to less than 25 YIP (5 < 25), while operators with ≥25 YIP had higher odds of a high severity (but not any) AE (OR 1.39, 95% CI 1.08-1.80). Operators with <5 YIP had a higher percentage of preventable AE (out of all AE, 16% vs. 8%, P < 0.001) as well as higher odds of vascular or cardiac trauma (OR 1.81, 95% CI 1.11-2.97), or technical AE (OR 1.98, 95% CI 1.31-2.99) when compared with operators with 5 < 25 YIP. There was no consistent relationship between operator volume, and incidence of AE. Operators with less than 5 years in practice have higher risk-adjusted AE rates. While an important consideration in guiding and mentoring operators with fewer years in practice, it is important to emphasize that reporting adverse events does not take into account procedural efficacy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call