Abstract

We examined the effect of the structure of corrosion inhibitors benzotriazole (BTA) and 1,2,4-triazole (TAZ) on the Cu removal rate during chemical mechanical planarization. Removal rates were higher for solutions containing TAZ than solutions containing BTA. Corrosion inhibitor films were characterized using atomic force microscopy, cyclic voltammetry, impedance spectroscopy, surface-enhanced Raman spectroscopy, and mass spectrometry. Inhibitor films formed from TAZ were thicker, more permeable, and rougher than films formed from BTA. The addition of glycine to the corrosion inhibitor containing solutions showed an increase in corrosion for the TAZ-covered Cu surface, little change for the BTA-covered surface, and an increase in removal rate for both systems. This study correlates removal rate with the physical properties of these two different corrosion inhibitors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.