Abstract

Diffused aeration is the most implemented method for oxygen transfer in municipal activated sludge systems and governs the economics of the entire treatment process. Empirical observations are typically used to regulate airflow distribution through the adjustment of manual valves. However, due to the associated degrees of freedom, the identification of a combination of manual valves that optimizes all performance criteria is a complex task. For the first time a multi-criteria optimization algorithm was used to minimize effluent constituents and energy use by parametrizing manual valves positions. Data from a full-scale facility in conjunction with specific model assumptions were used to develop a base-case facility consisting of a detailed air supply model, a bio-kinetic model and a clarification model. Compared to the base-case condition, trade-offs analysis showed potential energy savings of up to 13.6% and improvement of effluent quality for NH4+ (up to 68.5%) and NOx (up to 81.6%). Based on two different tariff structures of a local power utility, maximum costs savings of 12800 USD mo−1 to 19000 USD mo−1 were estimated compared to baseline condition.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.