Abstract

Objective: To observe the relationship between impaired myocardial untwisting and left ventricular diastolic dysfunction in patients with autoimmune diseases (AD). Methods: In this retrospective study, 95 AD patients (27 males, (38.6±14.2) years old) were enrolled as AD group and 71 gender and age matched healthy subjects (24 males, (37.6±12.2) years old) were enrolled as control group, all underwent transthoracic echocardiography and two-dimensional speckle-tracking echocardiography (STE) in our hospital between January 2014 and June 2018. Left ventricular untwisting and diastolic function parameters were measured. Multiple logistic regression analysis was used to identify related factors of left ventricular diastolic dysfunction in AD patients. Receiver operating characteristic (ROC) curve was used to identify the diagnosis value of untwisting parameters for left ventricular diastolic dysfunction in AD patients. Results: Compared with control group, left ventricular ejection fraction was lower (58(47, 66)% vs. 67 (62, 71) %, P<0.001), E/e' was higher (10.78 (7.28, 13.65) vs. 6.30 (5.55, 7.25) , P<0.001), isovolumic relaxation time was longer (73.5 (56.5, 88.0) ms vs. 62.0 (58.0, 68.5) ms, P<0.001),and untwist slope during isovolumic relaxation period (USIR) was lower (31.92 (14.09, 54.92) °/s vs. 59.90 (40.09, 87.18) °/s, P<0.001) in AD group than in control group. Multiple logistic regression analysis showed heart rate (OR=0.885, 95%CI 0.840-0.931, P<0.001), E/e' (OR=0.655, 95%CI 0.537-0.798, P<0.001) and USIR (OR=0.986, 95%CI 0.974-0.998, P=0.020) were independently related with left ventricular diastolic dysfunction in AD patients. ROC curve showed that area under the curve (AUC) was 0.919 (P<0.001), sensitivity was 87.6%, and specificity was 88.7%, when combining the heart rate, E/e', and USIR as assessment parameters for the diagnosis of left ventricular diastolic dysfunction in AD patients at a cutoff of 0.51. Conclusions: Impairment of myocardial untwisting indicates the presence of early stage left ventricular diastolic dysfunction in AD patients. USIR may be a sensitive parameter to evaluate early stage left ventricular diastolic dysfunction in AD patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.