Abstract

Break arcs are generated in a DC 42V-10A resistive circuit. The contact material is Ag or Ag/ZnO. The number of break operations is two hundreds for each contact material. The motion of break arcs is observed with a high-speed camera. Relationship between the dependence of arc duration on the number of operations and the motion of arc spots is investigated. The following results are shown. For Ag contacts the arc duration is almost constant independent to the number of break operations. For Ag/ZnO contacts, on the other hand, the arc duration changes irregularly to short (59 ms) or long (69 ms) arc-duration after 30th break operation. The moving range of arc spots on contact surfaces is broad for the case of short arc-duration and is narrow for the case of long arc-duration. The cause of the results for Ag/ZnO contacts is considered that the difference of the boiling points of Ag and ZnO leads to the porous structure on the contact surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.