Abstract

Pain is an important consideration in the performance of needle electromyography (EMG). Prior investigations have suggested that pain is greater with a concentric needle electrode (CNE) than monopolar needle electrode (MNE). This prospective randomized study tested this hypothesis using improved methodology and disposable rather than reusable needle electrodes. Ninety consecutive outpatients were enrolled and randomized to CNE (diameter = 0.46 mm) or MNE (diameter = 0.41 mm) arms. Subjects underwent a standardized 4 limb-muscle needle EMG protocol during which pretest and posttest verbal analog pain scale (0–10) measures were obtained. As anticipated, EMG-induced pain was significantly higher (P < 0.001) than pre-EMG baseline pain. However, analysis of variance (ANOVA) revealed no significant differences in pain ratings between the CNE and MNE arms. Among other factors analyzed, only gender significantly influenced EMG-induced pain, with females reporting higher levels than males. Thus, pain is not an important selection criterion for type of disposable needle electrode. © 2001 John Wiley & Sons, Inc. Muscle Nerve 24: 417–420, 2001

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.