Abstract

Active expiration during exercise can increase intrathoracic pressure yielding concavity in the expiratory flow-volume loop in COPD. We investigated the relationship between this concavity and dynamic hyperinflation (DH). 17 COPD patients (FEV1: 38±10%pred, GOLD stage 3–4) and 12 healthy subjects performed cycle ergometer incremental exercise. Expiratory limb of the spontaneous flow-volume loop was analyzed breath-by-breath using a geometric approach (rectangular area ratio (RAR), Respir. Med., 104(3):389–96, 2010). RAR below 0.5 demonstrates expiratory limb concavity. DH was determined with serial inspiratory capacity maneuvers. 5 of 17 patients displayed little end-exercise concavity (RAR=0.52±0.04, group LCONC). 12 patients had concavity at rest and end-exercise RAR reached 0.40±0.03 (group HCONC). Healthy subjects showed no concavity. End-exercise RAR correlated with resting FEV1%pred (R2=0.81, P<0.05). Group HCONC, compared to groups LCONC and H, reached significantly lower work rate, minute ventilation, and more dyspnea. DH inversely correlated with RAR (R2=0.81, P<0.05). Detection of concavity in spontaneous flow-volume loops may help assess DH and exercise limitation in COPD.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call