Abstract

PurposeTo investigate accommodative microfluctuations (AMFs) and visual function in short tear break-up time (BUT)-type dry eye (DE) and non-DE subjects.MethodsThis prospective comparative study included 48 volunteers with DE symptoms (mean age 34.8 ± 5.5 years, age range 25–42 years) and 73 without DE symptoms (mean age 30.6 ± 4.7 years, age range 25–42 years). The eyes were divided into two groups: (1) DE group with DE symptoms and BUT ≤ 5 s and (2) non-DE group without DE symptoms and BUT > 5 s. We excluded eyes with Schirmer score ≤ 5 mm and positive keratoconjunctival epithelial damage. Tear evaluation, AMF, and functional visual acuity (VA) examinations were performed. AMF parameters included total high-frequency component (HFC), HFC with low accommodation for the task of staring into the distance (HFC1), and HFC with high accommodation for deskwork (HFC2). Functional VA parameters included starting VA, functional VA, visual maintenance ratio, and blink frequency.ResultsA total of 33 and 34 eyes were categorized in the DE and non-DE groups, respectively. Mean blink frequency and HFC1 values were significantly higher in the DE group than they were in the non-DE group.ConclusionsDEs with symptoms showed abnormal AMF and visual function, which may be associated with DE symptoms.

Highlights

  • The International Dry Eye Workshop (DEWS) specifies two major classes of dry eye (DE) disease [1]

  • Mean blink frequency and HFC1 values were significantly higher in the DE group than they were in the non-DE group

  • DEs with symptoms showed abnormal accommodative microfluctuations (AMFs) and visual function, which may be associated with DE symptoms

Read more

Summary

Methods

This prospective comparative study included 48 volunteers with DE symptoms (mean age 34.8 ± 5.5 years, age range 25–42 years) and 73 without DE symptoms (mean age 30.6 ± 4.7 years, age range 25–42 years). The eyes were divided into two groups: (1) DE group with DE symptoms and BUT 5 s and (2) non-DE group without DE symptoms and BUT > 5 s. We excluded eyes with Schirmer score 5 mm and positive keratoconjunctival epithelial damage. AMF, and functional visual acuity (VA) examinations were performed. AMF parameters included total high-frequency component (HFC), HFC with low accommodation for the task of staring into the distance (HFC1), and HFC with high accommodation for deskwork (HFC2). Functional VA parameters included starting VA, functional VA, visual maintenance ratio, and blink frequency

Conclusions
Introduction
Participants
Discussion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call