Abstract

The corrosive issues are comprehensively caused in oilfield rejection system, in which sulfide is one of (bio-)chemical factors leading to high corrosive rate and blocking problem. Generally, aerobic treatment is a well-established and cost-effective unit for sulfide removal before oilfield wastewater reinjection. However, the residual dissolved oxygen (DO), which causes chemical, biological and electrochemical corrosion to water injection pipeline equipment, is still high after multi-stage filtration of DO removal. Here, a novel system to achieve quick and efficient DO removal through a three-electrode (cathode-anode-cathode)-upflow bioelectrochemical reactor (RCAC) was constructed before wastewater reinjection. Bioelectrodes were well established by utilizing organic matters of oilfield wastewater and conducted extracellular electron transport to achieve a steady DO removal from ∼5mg/L to 0.01mg/L (HRT 6h), the DO removal efficiency reached approximately 100%, and the downside biocathode made the largest contribution for DO removal. In the treated wastewater, the corrosion rate of stainless steel N80 ultimately declined over 30 days testing. As a result of DO removal and ammonia conversion to nitrate by bioelectrodes, the corrosive microorganisms were substantially changed. Especially, sulfate-reducing bacteria (SRB) on the surface of N80 immersed in treated wastewater were decreased in abundance; while nitrate-reducing bacteria (NRB) enriched more, which can compete with SRB to prevent biological corrosion.