Abstract

A vertical shear connector suitable for manufacture by automated sheet metal processes from steel coil is developed in an experimental program involving 90 small area bearing tests, 18 shear tests, and 6 tension tests. A comparison of three full‐scale wall panel tests (standard cavity wall, cavity wall with an unbonded steel mullion, and cavity wall with a vertical shear connector) demonstrate that the connector significantly increases both the post‐ and pre‐cracking strength and stiffness of a vertically spanning brick masonry cavity wall under out‐of‐plane loads.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.