Abstract

The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.

Highlights

  • The incorporation of crystalline particles inside glasses matrices enables dental ceramics to reach high fracture resistance due to smaller crack propagations without compromising the final aesthetics [1]

  • Among the main ceramics used in dentistry, lithium disilicate ceramics are noteworthy for their extensive indication: veneers, inlays, onlays [1], monolithic crowns [1,2], copings, fixed prostheses [1], hybrid abutments [3] and endocrowns [4]

  • The goal of this study was to compare the volume loss and the depth of wear generated after wear simulation in two dental ceramics using a three-dimensional parametric inspection and scanning electron microscopy

Read more

Summary

Introduction

The incorporation of crystalline particles inside glasses matrices enables dental ceramics to reach high fracture resistance due to smaller crack propagations without compromising the final aesthetics [1]. Among the main ceramics used in dentistry, lithium disilicate ceramics are noteworthy for their extensive indication: veneers, inlays, onlays [1], monolithic crowns [1,2], copings, fixed prostheses [1], hybrid abutments [3] and endocrowns [4]. Another ceramic with a similar function is zirconia reinforced lithium silicate, possessing reinforcement crystals in the monosilicate phase instead of disilicate. Long-term investigations should be performed to evaluate the behavior of these materials

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.