Abstract

The purpose of this study is to analyze and compare six automatic intensity-based registration methods for intraoperative infrared thermography (IRT) and visible light imaging (VIS/RGB). The practical requirement is to get a good performance of Euclidean distance between manually set landmarks in reference and target images as well as to achieve a high structural similarity index metric (SSIM) and peak signal-to-noise ratio (PSNR) with respect to the reference image. In this study, preprocessing is applied to bring both image types to a similar intensity. Similarity transformation is employed to align roughly IRT and visible light images. Two optimizers and two measures are used in this process. Thereafter, due to locally different displacement of the brain surface through respiration and heartbeat, two non-rigid transformations are applied, and finally, a bicubic interpolation is carried out to compensate for the resulting estimated transformation. Performance was assessed using eleven image datasets. The registration accuracy of the different computational approaches was assessed based on SSIM and PSNR. Additionally, five concise landmarks for each dataset were selected manually in reference and target images and the Euclidean distance between the corresponding landmarks was compared. The results are showing that the combination of normalized intensity, mutual information measure with one-plus-one evolutionary optimizer in combination with Demon registration results in improved accuracy and performance as compared to all other methods tested here. Furthermore, the obtained results led to [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] registrations for datasets 1, 2, 5, 7, and 8 with respect to the second best result by calculating the mean Euclidean distance of five landmarks. We conclude that the mutual information measure with one-plus-one evolutionary optimizer in combination with Demon registration can achieve better accuracy and performance to those other methods mentioned here for automatic registration of IRT and visible light images in neurosurgery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.