Abstract
Regional myocardial blood flow was studied in the anaesthetized dog by determining the distribution of 15 and 50μ radioactive microspheres after left atrial injection. Doses of the 15μ spheres below 4 × 106 did not significantly alter coronary or systemic haemodynamics. Larger doses produced a significant increase in mean aortic pressure. Less than 1% of the 15μ spheres delivered to the heart passed into the coronary sinus. The myocardial distribution of 15 and 50μ spheres was not significantly different except for the ratio of left ventricular endocardium to epicardium (1·12 for 15μ and 1·45 for 50μ, P<0.001). Using 15μ spheres, it was found that the ratio of endocardial to epicardial radioactivity in the left ventricular wall was increased by propranolol, decreased by isoprenaline, and unchanged by nitroglycerin.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.