Abstract

This paper proposes an energy regeneration circuit for three-phase voltage-fed inverters using a modified Undeland snubber. The proposed system uses a quasi-square-wave zero voltage switching dc-dc auxiliary converter to regenerate the energy from snubber capacitor to the dc bus. The regenerative circuit uses a single active switch, and it operates independently of the three-phase inverter. Operation stages, theoretical waveforms, and a design methodology are presented. Experimental results based on a 4.5-kVA three-phase inverter prototype are included to validate the proposed topology.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.