Abstract

The authors considered the processes of phase transformation of the working fluid in the compression unit of the freon circuit in the section “thermal expansion valve (TEV) - evaporator - compressor”. By adjusting the expansion valve under the conditions of the bubble mode of boiling of the refrigerant, the evaporation process takes place, accompanied by the achievement of a certain excess of steam temperature. Determination of rheological parameters (droplet size, vapor viscosity, refrigerant droplet vaporization rate) is necessary so that when moving from the throttle valve (TEV) to the compressor inlet, they have time to go into the vapor phase or return to the mass of boiling liquid. The article presents the results of an analytical calculation of the parameters of the kinetics of evaporation of Freon droplets as they move in a steam flow. The results of such an analysis make it possible to formulate requirements for the optimal droplet size in the created vapor-liquid mixture in order to ensure their maximum evaporation and the required thermal efficiency of the AHP as a whole. The established patterns of evaporation of refrigerant droplets can be used to select the design and operation of the AHP.