Abstract

We present a 39-year-old woman with high hyperopia who developed an intolerance to contact lenses due to dry-eye syndrome and Grave's disease. Refractive lensectomy with implantation of a custom-made +31.00 diopter (D) accommodating intraocular lens (IOL) (1CU, HumanOptics) was performed in both eyes. This foldable IOL has modified haptics with transmission elements that allow axial movement of the IOL optic and capsular bag secondary to contraction of the ciliary muscle. The calculated pseudophakic accommodation induced by the anterior shift of a +31.00 D IOL is 2.20 D per millimeter of axial displacement. After 6 months, the accommodative range determined by defocusing was 3.00 D. The subjective near point with best distance correction was 32.00 cm. Refractive lensectomy and implantation of an accommodating IOL based on focus shift may be a refractive solution in eyes with high hyperopia and a short axial length.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.