Abstract

To report the change in refraction in pseudophakic eyes following 23-gauge vitrectomy for epiretinal membrane (ERM), without use of silicone oil, intraocular gas or scleral buckling. Retrospective review of the records of 28 pseudophakic eyes in 28 patients undergoing 23-gauge pars plana vitrectomy for ERM. All 28 eyes had a measured preoperative refraction in their records and were seen minimum 2 months after vitrectomy for measuring their refraction. Fellow eyes (28 eyes) were used as controls. The mean preoperative refraction was -0.15 ± 0.85 dioptre (D), and the mean postoperative refraction was -0.41 ± 0.93 D. Thus, a myopic shift was observed following vitrectomy with a mean change in refraction of -0.26 ± 0.60 D (range +0.75 to -2.13 D, p = 0.032). The postoperative change in refraction was within ±0.25, ±0.50 and ±1.00 D in 39%, 68% and 96% of the eyes, respectively. The mean absolute refractive error was 0.47 ± 0.44 D. The change in refraction in fellow eyes was +0.01 D (p = 0.82). The change in refraction following 23-gauge pars plana vitrectomy for ERM in pseudophakic eyes was -0.26 D.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.