Abstract
Mechanical seal leakage of centrifugal pumps (especially hot oil pumps) is the main fault reason of the petrochemical equipments. The fuction of the sealing flush system is to maintain the mechanical shaft seal function correctly. The misconduct of flush system settings will directly lead to the failure of mechanical seal. In this paper, the problems are analyzed for the present mechanical seal flushing system. When the centrifugal pump is in a standby state, flushing system may not provide normal flush flow in self-flush plan. This may lead to surface fouling of the hot mechanical shaft seal, resulting in seal failure. Our research focus on solving these problems. The way is to change the source of flush fluid, that is to change the flush plan to external flush plan or toChange the fluid pipe position.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.