Abstract
In Korea, tests for evaluating respiratory muscle strength are based on other countries' clinical experience or standards, which can lead to subjective evaluations. When evaluating respiratory function based on the standards of other countries, several variables, such as the race and cultures of different countries, make it difficult to apply these standards. The purpose of this study was to propose objective respiratory muscle strength standards and predicted values for healthy Korean adults based on age, height, weight, and muscle strength, by measuring maximal inspiratory pressure (MIP), maximal expiratory pressure (MEP), and peak cough flow (PCF). This cross-sectional study analyzed MIP, MEP, and PCF in 360 people, each group comprising 30 adult men and women aged 20-70, diagnosed as healthy after undergoing medical check-ups at a general hospital. Hand grip strength (HGS) and the five times sit-to-stand test (FTSST) results were also recorded. Correlations among respiratory muscle strength, participant demographics, and overall muscle strength were evaluated using Pearson's correlation analysis. The predicted values of respiratory muscle strength were calculated using multiple regression analysis. Respiratory muscle strength differed from the values reported in studies from other countries. In the entire samples, both MIP and MEP had the highest correlations with peak HGS (r = 0.643, r = 0.693; P < 0.05), while PCF had the highest correlation with forced expiratory volume in 1 s (r = 0.753; P < 0.05). Age, body mass index, peak HGS, and FTSST results were independent variables affecting respiratory muscle strength. A predictive equation for respiratory muscle strength was developed using the multiple regression equation developed in this study. Respiratory muscle strength index may differ by country. For more accurate diagnoses, standard values for each country are required. This study presents reference values for Korea, and a formula for estimation is proposed when no respiratory muscle strength measurement equipment is available. Clinical Research Information Service Identifier: KCT0006778.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.