Abstract

Potentiometric CO2 gas sensors with Li conducting glasses/glass ceramics of the system Li2O-Al2O3-SiO2 (different nominal composition) as solid electrolytes have been investigated. Li2CO3 was used as CO2 and O2 sensitive auxiliary electrode. During the sensor test measurements, the CO2 partial pressure was varied between 1×10−3 and 1×10−1 bar at a constant O2 partial pressure of 2.1×10−1 bar whereas N2 was used as carrier gas. Comparative measurements were accomplished with sensors comprising Na and K ion conducting glasses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.