Abstract

Ionization chamber dosimetry is predominantly used for determination of the absorbed dose to water in 60Co and high-energy radiotherapy photon beams. The most widespread ionization chambers employed for absolute or reference dose determinations in reference conditions are the Farmer-type cylindrical ionization chambers. The Farmer-type ionization chambers have a variety of constructions and materials and their responses vary in the radiation beam. Clinical accelerators, in addition to conventional photon beams with flattening-filter, can also deliver flattening-filter-free (FFF) photon beams. The responses of five different Farmer-type cylindrical ionization chambers were experimentally examined with reference to absorbed dose determination in reference conditions when using the International Atomic Energy Agency (IAEA) - American Association of Physicists in Medicine (AAPM) Technical Reports Series no. 483 (TRS-483) and the IAEA TRS-398 dosimetry protocol in the present investigation. The irradiations were performed using 60Co and megavoltage photon beams with 6 MV, 15 MV, 6 MV FFF and 10 MV FFF nominal photon energies. The chamber calibrations were performed at different Secondary Standard Dosimetry Laboratories and are traceable to primary standards at different Primary Standard Dosimetry Laboratories. The chambers were also cross-calibrated at our laboratory using 60Co γ-beam. The variation found in the data regarding the reference dose determination using the various Farmer-type chambers in the photon beams employed was about 1% at maximum. Thus, the selection of the ionization chamber in reference dose determinations may affect the outcomes. The differences in the absorbed dose values were similar in the conventional as well as in the FFF photon beams. For the FFF photon beams the absorbed dose computations were performed using the IAEA-AAPM TRS-483 dosimetry protocol. Two of the ionization chambers used had identical construction but different central electrodes, i.e. graphite versus aluminium. The results obtained using these two chambers show that, in the photon beams examined, the employed correction for the central electrode (pcel) regarding these two chambers is associated with an inaccuracy which is larger than the calculated uncertainty for this correction. The outcomes found in the present experimental investigation using the various ionization chambers also indicate possible inaccuracy in the employed beam quality correction factors (kQ) and imply the need for a revision of these factors.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call