Abstract
This study proposed a control method to reduce the torque ripple vibration of an integrated on-board charger using the windings of an interior permanent magnet synchronous motor (IPMSM). During a battery-charging operation, stopping the motor results in noise, as well as damage to the motor and other components from the torque vibration caused by the charging current. In the proposed control method, the generated torque was estimated using a back-electromotive force table, and the phase current was controlled to eliminate the torque. The proposed method can suppress torque vibration, irrespective of the angle of the rotor in the IPMSM. The effectiveness of the proposed method was verified experimentally, with the torque vibration suppressed by 94% compared with that of the conventional control method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.