Abstract

The paper presents an analysis of heat loss and reductions of annual emissions of air pollutants of a quadruple pre-insulated heating network by comparing this solution with the existing pre-insulated network consisting of four pre-insulated single pipes and the variant consisting of two twin pipe pre-insulated. For calculations, an existing heating network located in central Poland was adopted, where heat is transported for heating purposes of buildings and domestic hot water with circulation of domestic hot water through four separate pre-insulated underground pipes. The idea of the construction of four pre-insulated pipes presented in the paper consists in the location of four steel pipes in a common round thermal insulation, which perform the role of heat transport for heating purposes in multi-family buildings (supply and return) and two pipes transporting hot water (a pipe with domestic hot water with circulation). In Poland, heating pipes used in multi-family housing have a larger diameter compared to domestic hot water pipes, which is why standard twin pipe heating pipes have been used in the construction of four pre-insulated networks, in which the domestic hot water pipe has been added to the thermal insulation and circulation of domestic hot water. In order to determine heat losses, a simplified two-dimensional model of conductive heat transfer was developed using Fortran to create a computer program. The results of numerical simulations show that the use of twin pipes for the construction of pre-insulated quadruple networks has contributed to a significant reduction in heat loss in relation to the existing single pre-insulated network (up to 57.1%), while reducing the thermal insulation field of the cross-section of the pre-insulated pipe by 21.4%.

Highlights

  • Energy-efficient operation of heating networks is primarily associated with the reduction of heat losses in pre-insulated pipes

  • Reduction of heat loss in heating networks can be achieved by using thicker layers of thermal insulation or heating networks with a lower thermal conduction coefficient of thermal insulation, which is associated with a higher cost of heating networks

  • Standard thermal insulation in twin pipe ducts used for heat transport allows the placement of two additional smaller diameter pipes compared to heating pipes

Read more

Summary

Introduction

Energy-efficient operation of heating networks is primarily associated with the reduction of heat losses in pre-insulated pipes. Heat losses in single pre-insulated pipes can be determined using analytical methods [3,7,9,12,13] as well as using numerical methods in two-dimensional [10,12] and three-dimensional [14] problems. The boundary element method is a non-mesh method and for given boundary conditions in the form of temperature or heat flux, it allows the determination of heat fluxes for individual pipes inside thermal insulation. It should be noted that in the case of single heating networks and twin pipes, analytical formulas may be used to determine heat losses, the results of which are consistent with the results of numerical methods [12], while in the case of pre-insulated quadruple heating pipes in common thermal insulation, analytical formulas are not known.

Analysisfraction of Heat φ
Statistical Descriptors and Reconstruction
Geometry
Percentage
Conclusions
Findings
Methods
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call