Abstract
In this work a theoretical model to evaluate the capabilities of our lidar system in forest fire detection is reported. In particular, a new idea of minimization of false alarm is shown. In a forest fire, in fact, a lot of ashes and in the first stage a large amount of water vapour are emitted. Measurements of water vapour increase with respect to standard humidity in the atmosphere due to a forest fire event, by means of Raman analysis, permit to minimize the false alarm. A simulation of one case of study permits to estimate the maximum range of detection and minimum sensibility of our lidar system. In this paper the theoretical results are shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.