Abstract

BackgroundTo compare irradiation dose to the second and third portions of duodenum (Duo2 and Duo3) with a new refined and old delineation method of para-aortic region for patients with locally advanced cervical cancer (LACC) receiving prophylactic extended-field radiotherapy (EFRT).MethodsTwenty consecutive patients with LACC were treated with prophylactic EFRT from January 2016 to January 2017 at our institute. Two delineation methods of para-aortic region were designed for each patient, the old delineation method ensured a full coverage of aortic and inferior vena cava, while the right paracaval region above L3 was omitted from CTV in the new delineation method. Patients received a dose of 50.4Gy in 28 fractions for PCTV and a dose of 60.2Gy in 28 fractions for PGTV with volumetric-modulated arc therapy (VMRT). The dose delivered to Duo2 and Duo3 with these two delineation methods were compared.ResultsAll treatment plans achieved excellent target volume coverage with 95% of PCTV receiving 50.4Gy and 95% of PGTV receiving 60.2Gy. There was no difference between delineation methods in low dose level (V5, V10, V15, V20, V25) for Duo2 and Duo3. The V30, V35, V40, V45, V50, Dmax, Dmean and D2cc for Duo2 with the new and old delineation methods were 55.76% vs 80.54% (P = 0.009), 34.72% vs 70.91% (P < 0.001), 18.69% vs 55.46% (P < 0.001), 8.20% vs 41.49% (P < 0.001), 1.86% vs 21.60% (P < 0.001), 49.58Gy vs 52.91Gy (P = 0.002), 30.38Gy vs 39.22Gy (P = 0.001) and 37.90Gy vs 48.64Gy (P < 0.001) respectively. For Duo3, the new delineation method achieved significant advantages in V30, V35, V40, V45, V50 and Dmean over the old one (96.82% vs 99.25%, P = 0.021; 89.65% vs 97.21%, P = 0.001; 79.50% vs 93.18%, P < 0.001; 65.63% vs 82.93%, P < 0.001; 43.39% vs 65.60%, P < 0.001; 46.09Gy vs 49.24Gy, P < 0.001), no deference was observed regarding D2cc and Dmax with these two delineation methods.ConclusionWith the new delineation method of para-aortic area in prophylactic EFRT, significant reduction of irradiation dose to the second and third portions of duodenum in high dose area was obtained. This may further lower the incidence of duodenal toxicity when performing prophylactic EFRT for patients with LACC.

Highlights

  • To compare irradiation dose to the second and third portions of duodenum (Duo2 and Duo3) with a new refined and old delineation method of para-aortic region for patients with locally advanced cervical cancer (LACC) receiving prophylactic extended-field radiotherapy (EFRT)

  • A meta-analysis showed that the sensitivities for compute tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography/CT (PET/CT) in the detection of positive lymph nodes were 50, 56, and 82%, respectively [3]

  • Clinical target volume (CTV) plus a 7-10 mm margin was defined as planning clinical target volume (PCTV)

Read more

Summary

Introduction

To compare irradiation dose to the second and third portions of duodenum (Duo and Duo3) with a new refined and old delineation method of para-aortic region for patients with locally advanced cervical cancer (LACC) receiving prophylactic extended-field radiotherapy (EFRT). Duodenum is adjacent to the para-aortic region and portions of the organ are immobile, especially for the second portion (descending) and the third portion (transverse) [7]. All these factors may expose the duodenum to high dose irradiation and cause high incidence of radiation related toxicities when performing EFRT. A study from MD Anderson cancer center found that the 3-year actuarial rate of any duodenal toxicity was 11.7% for patients with gynecologic cancer receiving para-aortic lymph nodes irradiation [8]

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call