Presently, CR-39 Solid State Nuclear Track Detectors (SSNTD) is being used for Fast Neutron Personnel Monitoring in India. Individual detectors are cut manually from CR-39 sheets. Laser-cutting of the sheets will ensure precision and also save on the laborious efforts involved in sheet cutting. It was observed that there is a slight increase in background tracks due to laser-cutting. Studies were carried out on the effect of chemical pre-etching at higher temperatures in properties of CR-39 such as the background, sensitivity and minimum measurable dose. For this purpose a pre-etch step was included in the normal processing of the CR-39 foils in an elevated temperature electrochemical cell (ETECE cell) and the duration for pre-etch step at elevated temperature was optimized.