Abstract
Results of updating the reducer between the LPC and the condenser involving removal of lens compensators and stiffening of the bar and rib frames are presented. Air inflows into the vacuum system through cracks in welded joints of flexible elements with total welded length of 240 m are lowered considerably by replacing them by stiff sheet structures. Computations of the thermal and stress-strain states of the system are performed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.