Abstract

Surface contamination with the antineoplastic drugs cyclophosphamide, ifosfamide, and 5-fluorouracil was compared in 22 US hospital pharmacies following preparation with standard drug preparation techniques or the PhaSeal® closed-system drug transfer device (CSTD). Wipe samples were taken from biological safety cabinet (BSC) surfaces, BSC airfoils, floors in front of BSCs, and counters and analyzed for contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil. Contamination was reassessed several months after the implementation of the CSTD. Surface contamination (ng/cm(2)) was compared between the two techniques and evaluated with the Signed Rank Test. Using the CSTD compared to the standard preparation techniques, a significant reduction in levels of contamination was observed for all drugs (cyclophosphamide: p < 0.0001; ifosfamide: p < 0.001; 5-fluorouracil: p < 0.01). Median values for surface contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil were reduced by 95%, 90%, and 65%, respectively. Use of the CSTD significantly reduces surface contamination when preparing cyclophosphamide, ifosfamide, and 5-fluorouracil as compared to standard drug preparation techniques.