Abstract

Reduced mouth opening may be a major contributing factor to the deterioration in the view obtained at laryngoscopy when a semi-rigid cervical collar is in place. We set out to assess the degree to which mouth opening is restricted by a cervical collar. We measured maximal inter-incisor distance in 52 volunteers. It was measured again after application of each of three appropriately sized semi-rigid cervical collars (Stifneck, Miami J, and Philadelphia). Inter-incisor distance was significantly reduced by the application of a cervical collar [No collar 41 (7) mm-mean (SD); Stifneck 26 (8) P<0.0001; Miami J 29 (9) P<0.0001; Philadelphia 29 (9) P<0.0001]. There was a wide and unpredictable variation between subjects in the reduction in mouth opening and a significant proportion had an inter-incisor distance of 20 mm or less (Stifneck, 25%; Miami J, 21%; Philadelphia, 21%). Application of a semi-rigid cervical collar can significantly reduce mouth opening. This could hinder definitive airway placement. Our results support removing the anterior portion of the collar before attempts at tracheal intubation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.