The article presents the results of scientific research on the operation of pumping equipment at reclamation pumping stations. In pumping stations, more and more attention is being paid to measures to maintain the reliability and efficiency of pumping units and reduce the negative impact of factors of various origins. One of the most significant factors affecting the service life of the equipment is the increased vibration of the pumping unit. According to the analysis of failures of pumping equipment at pumping stations in Uzbekistan for 2010-2021, more than 40% of the pump stops occurred due to increased vibration. The most common cause of vibration of pumping equipment is waterjet and cavitation wear of the impeller, destruction of seals, wear, and temperature rise of the bearing. The greatest vibration occurs when the equipment is operated in heavy and non-optimal modes. As a result of the generalization of the research results, active methods and means of reducing the vibration of pumping units were identified.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.