Abstract
Ventilator-associated pneumonia is the most common intensive care unit-acquired infection. Although there is widespread consensus that evidenced-based interventions reduce the risk of ventilator-associated pneumonia, controversy has surrounded the importance of implementing them as a "bundle" of care. This study aimed to determine the effects of implementing such a bundle while controlling for potential confounding variables seen in similar studies. A before-and-after study conducted within the context of an existing, independent, infection surveillance program. An 18-bed, mixed medical-surgical teaching hospital intensive care unit. All patients admitted to intensive care for 48 hrs or more during the periods before and after intervention. A four-element ventilator-associated pneumonia prevention bundle, consisting of head-of-bed elevation, oral chlorhexidine gel, sedation holds, and a weaning protocol implemented as part of the Scottish Patient Safety Program using Institute of Health Care Improvement methods. Compliance with head-of-bed elevation and chlorhexidine gel were 95%-100%; documented compliance with "wake and wean" elements was 70%, giving overall bundle compliance rates of 70%. Compared to the preintervention period, there was a significant reduction in ventilator-associated pneumonia in the postintervention period (32 cases per 1,000 ventilator days to 12 cases per 1,000 ventilator days; p<.001). Statistical process control charts showed the decrease was most marked after bundle implementation. Patient cohorts staying ≥6 and ≥14 days had greater reduction in ventilator-associated pneumonia acquisition and also had reduced antibiotic use (reduced by 1 and 3 days; p=.008/.007, respectively). Rates of methicillin-resistant Staphylococcus aureus acquisition also decreased (10% to 3.6%; p<.001). Implementation of a ventilator-associated pneumonia prevention bundle was associated with a statistically significant reduction in ventilator-associated pneumonia, which had not been achieved with earlier ad hoc ventilator-associated pneumonia prevention guidelines in our unit. This occurred despite an inability to meet bundle compliance targets of 95% for all elements. Our data support the systematic approach to achieving high rates of process compliance and suggest systematic introduction can decrease both infection incidence and antibiotic use, especially for patients requiring longer duration of ventilation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.