Abstract

Gavage is a common technique for orally administering compounds to small laboratory animals using a syringe. It involves highly repetitive thumb extensor exertions for filling the syringe, a risk factor for DeQuervain’s tenosynovitis. As an intervention, a series of bench tests were performed varying fluid viscosity, syringe size and needle size to determine the forces required for drawing fluid. Forces up to 28 N were observed for a viscosity of 0.29 Pa s. A guide is presented to minimize thumb forces for a particular combination of syringe (3 mL, 5 mL and 10 mL), fluid viscosity (0.001 Pa s, 0.065 Pa s, 0.21 and 0.29 Pa s), and needle length (52 mm, 78 mm and 100 mm) based on maximum acceptable exertion levels. In general, a small syringe and large needle size had a greater number of acceptable rat gavages per day due to the lower forces experienced as compared to all other syringe and needle combinations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.