The purpose of this study is to provide direct evidence for the role of intercellular communications in electrical synchronization and mechanical function of myocardium. We used heptanol, a reversible inhibitor of gap junctions, at low (0.16 mM) and high (0.5 mM) concentration as perfusate for 18 Langendorff-perfused rabbit hearts to study its effects on myocardial electrical and mechanical functions. Optical mapping was performed to measure conduction velocity (CV) and action potential duration (APD). Ultrasonic integrated backscatter and Doppler tissue imaging (DTI) were used to evaluate the intrinsic and global myocardial contractile performance. The CV decreased during low-dose heptanol infusion and became much slower at high dose (high dose vs. baseline, 50.8 ± 10.2 cm/s vs. 69.3 ± 8.8 cm/s, p < 0.001). After washout of heptanol, CV completely recovered. The alterations of APD by heptanol infusion were similar to CV. The APD dispersion, standard deviation of APD 80, was increased after heptanol infusion (low dose vs. baseline, 5.9 ± 1.1 ms vs. 4.3 ± 1.1 ms, p = 0.004; high dose, 6.0 ± 1.3 ms, vs. baseline, p = 0.035). However, washout did not restore the APD dispersion which became even larger after washout (13.6 ± 1.9 ms vs. high dose and baseline, both p < 0.001). Regarding contractile function, heptanol treatment resulted in a progressive decrease of cardiac cycle-dependent variations of integrated backscatter (CVIBS; low dose vs. baseline, 6.1 ± 1.7 dB vs. 7.2 ± 1.8 dB, p = 0.007; high dose 1.7 ± 0.3 dB vs. baseline, p < 0.001) and peak systolic strain rate (low dose vs. baseline, −1.5 ± 0.6 1/s vs. −1.9 ± 0.6 1/s, p = 0.014; high dose −0.4 ± 0.2 1/s; vs. baseline, p < 0.001). That both CVIBS and strain rate incompletely recovered after heptanol washout may be attributed to the increased APD dispersion. In conclusion, uncoupling of gap junctions resulted in slowing CV, increased repolarization heterogeneity, reduced CVIBS and impaired myocardial contractility. There was a reversible dose–response relationship between the myocardial electromechanical functions and gap junction coupling. (E-mail: yenbin@ntu.edu.tw)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.