Abstract

PurposeChildren are exposed to significant radiation doses during the investigation and treatment phases of scoliosis. EOS is a new form of low-dose radiation scan which also yields great image quality. However, currently its use is discouraged in the UK due to higher costs. We aimed to quantify the additional radiation dose and cancer risk.MethodsWe retrospectively reviewed all paediatric cases who received both standing whole spine roentgenograms and EOS scans as part of their investigations for scoliosis during a six-month period. We compared the radiation doses between the two modalities and estimated the additional mean lifetime cancer risk per study.ResultsWe identified 206 children (mean age 14.4) who met the criteria of having both scans. Dose area products (dGycm2) were converted to estimated effective doses (mSv). The total mean doses were 0.68 mSv (PA 0.49 + Lat 0.19) for plain films, and 0.13 mSv (PA 0.08 + Lat 0.04) for EOS scans (p < 0.001). Additional lifetime cancer risk of a plain film was 543% greater than EOS for both sexes (1/10727 versus 1/5827 in males, 1/34483 versus 1/6350 in females).ConclusionThere is approximately 5.4-fold increase in risk of cancer for both boys and girls with roentgenograms over EOS, with girls being the most impacted. This carries a significant impact when considering the need for repeat imaging on additional lifetime malignancy risk in children. In our opinion, EOS dual planar scanning is the new gold standard when X-ray of the whole spine is required.Level of evidence III.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call