Abstract

A high transient current occurring when starting up an induction motor can lead to voltage dip. This paper proposes a method of induction motor soft-starting by using magnetic energy recovery switch (MERS). The MERS is a series compensation device and is able to control motor terminal voltage. The design of MERS control system is described. The starting current produced can be controlled by setting up the MERS firing angle. Experimental results confirmed that starting current can be reduced by applying MERS in series with induction motor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.