Abstract

Electric heater defrosting (EHD) is effective in removing frost on the evaporator and in recovering capacity/coefficient of performance (COP) for frost-free refrigerators. This study proposes a method of reducing the temperature rise in the freezing cabinet (FC) during the EHD process. Based on the idea of blocking the infiltration passage of the heater-generated warm air, a special cover was designed for the axial fan of the evaporator; the cover was kept open during cooling cycles to supply cold air into cabinets normally, but was forced closed during EHD cycles so that defrost heat was prevented from infiltrating into the FC. Results show that defrost duration was shortened by 3.4%, FC temperature rise within the defrost cycle declined by 1.6 °C, and the overall energy consumption for defrost and recovery cycles altogether was reduced by 1.9% with the fan cover. Further optimization could be made by adjusting the delay of the fan starting after defrosting.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.