Abstract

The implementation of groundwater conservation measures has forced utilities with a historical reliance on groundwater sources to consider alternative sources to augment their supplies or to eliminate their groundwater dependence. Switching from traditional source water, however, can cause unacceptable changes in water quality that result from destabilization and the release of chemical and biological films from the interior surfaces of the existing distribution systems. Data from a two‐year study were used to identify significant water quality parameters and to develop a predictive nonlinear model to estimate the corrosivity of blends based on water quality. The results of the statistical analysis indicate that alkalinity, chlorides, sulfates, sodium, and dissolved oxygen of the source water or blend of source waters have a significant effect on release of corrosion by‐products in the form of red water. Temperature and hydraulic retention time were the significant physical and operational parameters identified.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.