Abstract

The withdrawal of Cr-chromate has meant that the technique commonly used for direct measurement of red cell volume has had to be replaced. Most centres moved to a Tc erythrocyte label, however, Tc is known to dissociate over time. We have investigated an alternative technique using an In-chloride and tropolone solution and tested this both in vitro and in vivo. Initial in-vitro and in-vivo work, which included a check of the stability of the radio-labelled product at one hour, demonstrated this label to be stable over this time period. To date, 20 patients have undergone this technique and results show that this technique is a viable alternative to Cr-chromate particularly for patients with splenomegaly who require late sampling. This procedure is now in routine use in our institution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.