Abstract
In the present work, analytical models to predict the thermal and thermohydraulic efficiencies of two different designs of double pass packed bed solar air heater under external recycle have been proposed. It is predicted that Model A with the single air pass through the first channel as well as the recycle of the air exiting from the second channel through the third channel can enhance the heat transfer rate more as compared to Model B. The wire mesh screen as an absorbing media above the absorber plate is used in both of the solar air heater models. The recycle ratio and the mass flow rate are varied from 0.1 to 1 and 0.01–0.025 kg/s, respectively. The results of the study depict that the recycle ratio and the mass flow rate substantially increases the heaters efficiencies by increasing the fluid velocity. The maximum value of the thermal efficiency of Model A is found to be about 6.6% higher than that of Model B. The optimum values of the recycle ratio and the mass flow rate, at which the heaters yield maximum values of thermo-hydraulic efficiencies, are identified and presented. In addition, the effect of the channel depth ratio on the thermal performance improvement is also delineated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.