Abstract

A recursive domain decomposition approach based on a 2-D time-harmonic finite element (FE) model with AVI formulation is used to model a wireless power transfer (WPT) unit with litz wires. Similar techniques exist in the literature, but they have not yet been applied to WPT units. The approach produces a model that is significantly faster to update and resolve than a traditional FE model, and hence, it is suitable for performing parametric sweeps where the positioning of the coils is varied. Using the technique, it is possible to study losses emerging in individual strands even with an extremely high number of strands. The loss distribution between the litz wire strands is studied, varying the number of strands from 7 to 925. The results and speed are compared with a traditional FE AVI model. The method yields the results up to a 1% relative error compared with the traditional model with significantly faster simulation time.

Highlights

  • W IRELESS power transfer (WPT) systems can be used to transfer power without the need for physical contacts [1]

  • Parking squares and sections near traffic lights could be equipped with dynamic wireless charging coils that would boost the ranges of electric vehicles without the need for larger batteries [2]

  • For further details of the spatial decomposition technique, we refer to our earlier work [31] where we demonstrate the use of the Fourier basis for the Lagrange multiplier space in static magnetic field computations

Read more

Summary

Introduction

W IRELESS power transfer (WPT) systems can be used to transfer power without the need for physical contacts [1]. Parking squares and sections near traffic lights could be equipped with dynamic wireless charging coils that would boost the ranges of electric vehicles without the need for larger batteries [2]. In these kinds of applications, the WPT coils are perfectly aligned only for a short period of time, so it is crucial to analyze and optimize the operation of the windings when the coils are badly aligned. The load affects the operation of the WPT device On top of these considerations, there are several parameters that have a negative impact on the performance of the WPT unit. These parameters include offsets from the optimal position, variance in the distance between the windings, and misalignment of the magnetic axes of the windings

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.