Abstract

Study objective: To learn how to avoid injury to the carotid artery during recurrent pituitary surgery. Design: Through transsphenoidal endonasal approach the steps of surgery with avoidance of complications were described in the video particularly the use of Minidoppler was to localise the carotids. Setting: Comfort Nursing Home, a private hospital in Dhaka, Bangladesh. Subject/Audience: Neurosurgeons/Residents. Intervention: Demonstration of transsphenoidal endonasal approach for recurrent pituitary tumor and use of Minidoppler to avoid carotid artery injury. Results: Avoidance of complications like intraoperative accidental injury to carotids where symptomatic tumor is small and inter carotid distance is less. Taking this into account, we created this video to demonstrate the important steps specifically to use Minidoppler to avoid a devastation like carotid artery injury. Conclusion: The steps of recurrent pituitary surgery through endonasal approach is well established. To evaluate the details of anatomical structures specifically the inter carotid distance prior to surgery will prevent the unwanted complications in recurrent pituitary surgery and with high resolution monitoring and use of Minidoppler, carotid arteries can be localised.

Highlights

  • Design: Through transsphenoidal endonasal approach the steps of surgery with avoidance of complications were described in the video the use of Minidoppler was to localise the carotids

  • Avoidance of complications like intraoperative accidental injury to carotids where symptomatic tumor is small and inter carotid distance is less. We created this video to demonstrate the important steps to use Minidoppler to avoid a devastation like carotid artery injury

  • To evaluate the details of anatomical structures the inter carotid distance prior to surgery will prevent the unwanted complications in recurrent pituitary surgery and with high resolution monitoring and use of Minidoppler, carotid arteries can be localised

Read more

Summary

Introduction

Md Moshiur Rahman1*, Mainul Haque Sarker1 and Md Raziul Haque2 Study objective: To learn how to avoid injury to the carotid artery during recurrent pituitary surgery. Design: Through transsphenoidal endonasal approach the steps of surgery with avoidance of complications were described in the video the use of Minidoppler was to localise the carotids.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.