Abstract

Recurrent hemarthrosis is a rare complication after total knee arthroplasty (TKA). Its incidence is reported as less than 1%. Most patients present with acute knee pain and swelling in the absence of trauma, resulting in significant loss of function. The authors report a case of recurrent hemarthrosis in a 64-year-old female. She presented with repeated episodes of sudden-onset right knee pain, swelling, and bruising at 18 months after a right TKA. During revision knee surgery, the recurrent hemarthrosis was identified to have been caused by entrapment of hypertrophied knee synovium under the TKA tibial base plate. After excision of the synovial tissue and cementing of the tibial defect, the patient recovered well after surgery with no future recurrences of knee pain and swelling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.